2.
Using a soft cloth dampened with alcohol, wipe the hous-
ing clean of dirt.
1.
Clamp a soft cloth (gauze) dampened with alcohol with
tweezers and clean the Charge Wire in one direction.
Wipe from the Hook side to the Spring side.
1.
Use a blower brush to clean the Comb Electrode, Paper
Separator Corona.
1,
Use a soft cloth dampened with alcohol to clean the Pre-
Image Transfer Guide Plate.
1159D182AA
D-30
1159SBD0207, A
2-7. FUSING UNIT
(1) Removal of the Fusing Unit
1159D097AB
1159D088AB
1159D100AB
TI59D101AA
PN
os
11.
12,
Swing down the Front Door,
Release and swing up the Upper Half of the copier.
Removal three screws and the Middle Rear Left Cover.
Remove the Harness for the Fusing Unit from the Edge
Cover and remove it from the Cord Clamp.
Remove the two terminals for the Fusing Unit.
Remove the one screw, two washers and Ground Wire
from the Fusing Unit.
:
Remove the one Shoulder Screw, turn the Fusing Unit in
the direction of the arrow and remove it.
Remove one screw and the Bracket.
Remove the three screws and the Cover for the Fusing
Unit.
. Remove the one screw and front Heater Hamess.
Remove two scraws and the Fusing Thermoswitch.
Remove one screw and the Fusing Thermistors.