13, Remove the two screws and the front Power Supply Brush
Assy.
14, Remove the two screws and the rear Power Supply Brush
Assy.
1159D102AB
15. Remove two C-clips.
16. Remove one Spur Gear.
17, Remove the front and rear Bushings and remove the Roll-
or.
-_
1159D103AB
(2) Cleaning of the Upper Fusing Roller
1.
Using a soft cloth dampened with alcohol or siticone oll,
wipe clean the Upper Fusing Roller.
1.
Using a soft cloth dampened with alcohol or silicone oil,
wipe clean the Fusing Paper Separator Fingers.
1,
Using a soft cloth dampened with alcohol or silicone oil,
wipe clean the Fusing Thermistor TH1.
1169D106AA
D-32
(5) Cleaning of the Fusing Thermoswitch TS1
1.
Using a soft cloth dampened with alcohol or siligone oil,
wipe clean the Fusing Thermoswitch TS1.
1.
Remove the one screwand one washer, Liftthe Fusing En-
trance Guide in the direction of the arrow and remove.
2.
Remove the Lower Fusing Roller.
1.
Using a soft cloth dampened with alcoho! or silicone oil,
wipe clean the Lower Fusing Roller.
1,
Remove the Fusing Unit.
2.
Using a soft cloth dampened with alcohol, wipe clean the
Fusing Unit Entrance Guide Plate.
1159D183AA
D-33