2-6. PC DRUM CHARGE CORONA AND IMAGE TRANSFER/
PAPER SEPARATOR CORONAS
(1) Removal of the PC Drum Charge Corona
1.
Remove the two Covers.
2.
Remove the Ground-Shielded Harness Connector.
3.
Remove the Drum Charge Corona.
1159D091AB
(2) Cleaning of the Main Eraser
1.
Using a soft cloth dampened with alcohol, clean the Main
Eraser by gently wiping its surface in one direction.
1.
Press the Mesh Holder on the front of the Corona Unit in
the direction of arrow to remove the Grid Mesh.
1159D172AB
2.
Remove the End Cups from the front and rear end of the
Unit.
1159D173AB
D-28
3.
Remove the Comb Electrode, Drum charge Corona.
NOTE
Use care not to deform the Electrode. When removing it,
first snap off Its spring end.
1.
Use a blower brush to clean the Comb Electrode, Drum
charge Corona,
NOTE
if the blower brush is not effective in cleaning the Comb
Electrode, Drum Charge Corona use.a soft cloth damp-
ened with alcohol to clean serious contamination.
1.
Blow all foreign matter off the Grid Mesh a blower brush.
NOTE
ifthe blower brush is not effective in cleaning the Grid, use
a soft cloth dampened with alcohol to clean serious con-
tamination.
1.
Swing down the Front Door.
2.
Release and swing up the Upper Half of the copier.
3.
Pull out the Image Transfer/Paper Separator Coronas.
1.
Remove the Image Transfer/Paper Separator Corona
Housing.
1159D178AA
D-29