Communications Using the Direct Connection Function
Display Elements
10
S Lamps (page 151)
Allocated to: Bits
NT30/30C
Lamp #1 (IR/CIO 000100)
Lit
Unlit
Lamp #2 (IR/CIO 000101)
The PC's bit status can be displayed by lamps on the NT30/30C.
The lamp lights or flashes when the PC's bit status (i.e., the lamp bit) is ON (1),
and goes OFF when it is OFF (0).
Image/library lamps can also be created to switch the displayed image or li-
brary data according to the ON (1)/OFF (0) status of the lamp bit.
S Touch Switches (page 154)
Allocated to: Bits
Touch switch #12
NT30/30C
IR/CIO 009012
The PC bit allocated for the touch switch turns ON (1) and OFF (0) when the
touch switch is pressed to notify the PC of the status of the touch switch.
S Numeral Memory Table (page 138)
Allocated to: Words
Numeral memory
NT30/30C
table entry 1 (TIM003)
Numeral memory table entry 150 (IR/CIO 0005)
The numeral memory table is allocated to words in the PC. If word contents
change when corresponding numeral memory table entry is displayed on the
screen, the value on the screen will also change, enabling the contents of
words to be easily monitored.
Reading and writing are executed so that the contents of allocated words are
kept the same as those of the numeral memory table entries.
PC
Switch 1: ON (IR/CIO 000100)
Switch 2: OFF (IR/CIO 000101)
PC
IR/CIO 009012: ON
PC
Section
1-4