4.2.4.17 Transmission Holder Assy

The Main Frame becomes unstable once it is removed from the
Base Frame. Be careful not to deform the frame during
performing the following procedures.
◼ Refer to
4.2.4.11 Main Frame (p144)
need to be removed before removing the Main Frame.
Parts/Components need to be removed in advance:
Main Frame/Printhead/CR Scale/Carriage Unit/Ink System
Removal procedure
Push the Switch Lever in the direction of the arrow and disengage the
1.
Transmission Arm from the Transmission Holder Assy. (See
4-140.)
Remove the screw (x1) that secures the Transmission Holder Assy. (See
2.
4-140.)
Release the PE Sensor Cable from the Transmission Holder Assy, and remove
3.
the Transmission Holder Assy.
PE Sensor Cable
Transmission Holder Assy
Figure 4-140. Removing the Transmission Holder Assy
DISASSEMBLY/ASSEMBLY
for the Parts/Components
Fig.
4-86,
Fig.
Fig.
Switch Lever
Transmission Arm
C.B.P. 3x8 (6±1Kgfcm)
Disassembly Procedures
https://www.manualsbooks.com
Make sure that all gears on the Transmission Holder Assy are
properly installed to the hooks and move smoothly.
Figure 4-141. Installing the Transmission Holder Assy (1)
When assembling the Transmission Holder Assy, align the
hooks (x3) of the Transmission Holder Assy with the ribs (x3)
of the Main Frame.
Bottom side
Rib of the Main Frame
Figure 4-142. Installing the Transmission Holder Assy (2)
For routing the FFCs, see
4.4 "Routing FFC/cables"
Revision C
Hook
Transmission Holder Assy
Hook
(p202).