Epson Artisan 800/Epson Stylus Photo PX800FW/TX800FW/Epson Artisan 700/Epson Stylus Photo PX700W/TX700W

4.3.3.2 Scanner Upper Housing (Artisan 700/PX700W/TX700W)

Parts/Components need to be removed in advance:
Scanner Unit/ADF Unit/Document Cover
Removal procedure
◼ It is recommended to remove the Scanner Upper Housing in a
clean room or on a clean bench to keep away from dust and dirt.
Be careful not to damage the document glass on the Scanner
Upper Housing.
1.
Remove the screws (x7) that secure the Scanner Upper Housing.
Release the hooks (x3) that secure the Scanner Upper Housing.
2.
Bottom side
Figure 4-241. Removing the Scanner Upper Housing (1)
Scanner Upper Housing
C.B.P. 3x10 (5±1kgfcm)
Hook
C.B.P. 3x8 (5±1kgfcm)
https://www.manualsbooks.com
Release the ribs (x4) on the Scanner Upper Housing, and remove the Scanner
3.
Upper Housing in the direction of the arrow.
Figure 4-242. Removing the Scanner Upper Housing (2)
When installing the Scanner Upper Housing, see "
Upper Housing (Artisan 800/PX800FW/TX800FW)"
Revision C
Scanner Upper Housing
Rib
4.2.5.1 "Scanner
(p167)" .
Confidential