Loosen the screw (x1) that secures the Parallelism Bushing. (See
3.
Lift the PG Lever R and disengage the dowel of the Main Frame from the
4.
shaft hole of the Parallelism Bushing. (See
5.
Rotate the Parallelism Bushing till the screw that secures the CR Motor Assy
can be seen.
Right side
PG Lever R
Dowel &
Parallelism Bushing
shaft hole
C.B.S. 3x6 (Secure it after PG Adjustment)
Figure 4-125. Removing the CR Motor (2)
Remove the screws (x4) that secure the CR Motor, and remove the CR Motor
6.
Assy.
Right side
Figure 4-126. Removing the CR Motor (2)
DISASSEMBLY/ASSEMBLY
Fig.
4-125.)
Fig.
4-125.)
Right side
PG Lever R
The screw that
secures the CR Motor
Parallelism Bushing
CR Motor Assy
Positioning hole & dowel
C.B.S. 3x6 (8±1Kgfcm)
C.B.S. 3x4 (8±1Kgfcm)
Disassembly Procedures
https://www.manualsbooks.com
Be careful not to damage the Pinion Gear of the CR Motor with the
CR Motor Holder.
Remove the screws (x2) that secure the CR Motor, and remove the CR Motor
7.
from the CR Motor Holder.
CR Motor Holder
Figure 4-127. Removing the CR Motor (3)
Revision C
CR Motor
Groove
C.P. 3x4 (4±1Kgfcm)