Epson Artisan 800/Epson Stylus Photo PX800FW/TX800FW/Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Do not open/close the Scanner Unit with the screws removed to
avoid damage of the Scanner Unit Hinge.
Remove the screw (x1) that secures the Scanner Unit.
4.
Rear
Figure 4-7. Removing the Scanner Unit (2)
Lift the Hinge on the right side in the direction of the arrow (1) and slide the
5.
Scanner Unit in the direction of the arrow (2), and remove it.
Figure 4-8. Removing the Scanner Unit (3)
DISASSEMBLY/ASSEMBLY
C.B.P. 3x10 (black) (6±1Kgfcm)
Scanner Unit
Disassembly Procedures
https://www.manualsbooks.com
When installing the Scanner Unit, follow the procedure below.
Align and insert the dowel of the Scanner Unit to the
positioning hole of the printer (Left inside).
Align and insert the rib of the Scanner Unit to the groove of
the Hinge.
Left
inside
Dowel
Hole
Figure 4-9. Installing the Scanner Unit (1)
3. While aligning the screw holes with the Scanner Unit open,
secure them temporarily with the screw (x1) shown in
4-7. (It is recommended to prepare a pillow-shaped
supporter to keep this position.)
Secure it with the screw temporarily with the screw holes aligned.
Pillow-shaped supporter
Figure 4-10. Installing the Scanner Unit (2)
Revision C
Right
inside
Rib of the Scanner Unit
& groove of the Hinge
Fig.
(Continued to the next page.)
104