4.3.1.3 Upper Housing (Artisan 700/PX700W/TX700W)

The disassembly/reassembly procedures for Artisan 800/PX800FW/
TX800FW differ from those of Artisan 700/PX700W/TX700W, see
4.2.2.5 "Upper Housing" (p107)
Parts/Components need to be removed in advance:
Scanner Unit/Upper Left Housing/Paper Guide Top Assy
Removal procedure
The Grounding Wire is attached to the frame with a screw. Be
careful not to deform the frame when removing the screw.
Remove the screw (x1) and release the Grounding Wire.
1.
Wire
Figure 4-210. Releasing the Grounding Wire
DISASSEMBLY/ASSEMBLY
for the procedures.
C.B.S. 3x6 (8±1Kgfcm)
Disassembly/reassembly procedures specific to Artisan 700/PX700W/TX700W
https://www.manualsbooks.com
Release the hooks (x5) of the Panel Unit Front Cover. (See
2.
While pushing the Panel Lock Button, slide the Panel Upper Cover in the
3.
direction of the arrow to release the hook (x8) of the Panel Upper Cover, and
remove the Panel Upper Cover.
Panel Unit Front Cover
Panel Unit
Panel Lock Button
Hook of the Panel Upper Cover
Hook of the Panel Unit Front Cover
Figure 4-211. Removing the Upper Housing (1)
Revision C
Fig.
4-211)
Panel Upper Cover