• Accel time
Set the time needed for output frequency to reach 100% from 0%.
• Decel time
Set the time needed for output frequency to reach 0% from 100%.
(Maximum output frequency n09=100%)
Automatic restart after momentary
power loss (n47)
When momentary power loss occurs, operation restarts automatically.
Setting
Setting
Continuous operation after momentary power loss
Continuous operation after momentary power loss
0
0
not provided.
not provided.
Continuous operation after power recovery within
Continuous operation after power recovery within
1*
momentary power loss ridethru time
Continuous operation after power recovery (Fault
Continuous operation after power recovery (Fault
2*†
2*†
output not provided)
output not provided)
* Hold the operation command to continue the operation after recovery from a momentary
power loss.
† When 2 is selected, operation restarts if power supply voltage reaches its normal level while
control power supply is held. No fault signal is output.