• Typical setting of V/f pattern
Set the V/f pattern according to the application as described below. For
400V class, the voltage values (n10, n13, and n15) should be doubled.
When running at a frequency exceeding 50Hz/60Hz, change the maximum
output frequency (n09).
Note: Be sure to set the maximum output frequency according to the motor characteristics.
(1) For general-purpose applications
Motor Specification : 60Hz
V
200
12
1.5
60 f
(2) For fans/pumps
Motor Specification : 60Hz
V
200
50
10
1.5 30
60 f
(3) For applications requiring high starting torque
Motor Specification : 60Hz
V
200
24
18
1.5 3
60 f
Increasing voltage of V/f pattern increases motor torque, but an excessive
increase may cause motor overexcitation, motor overheat or vibration.
Note : n12 is to be set to motor rated voltage.
38
Setting
Constant
n09
60.0
n10
200
n11
60.0
n12
1.5
n13
12
n14
1.5
n15
12
Setting
Constant
n09
60.0
n10
200
n11
60.0
n12
30.0
n13
50
n14
1.5
n15
10
Setting
Constant
n09
60.0
n10
200
n11
60.0
n12
3.0
n13
24
n14
1.5
n15
18
Motor Specification : 50Hz
(Factory setting)
V
Constant
200
12
1.3
50 f
Motor Specification : 50Hz
V
Constant
200
50
10
1.3
25
50 f
Motor Specification : 50Hz
V
Constant
200
24
18
1.3 2.5
50 f
Setting
n09
50.0
n10
200
n11
50.0
n12
1.3
n13
12
n14
1.3
n15
12
Setting
n09
50.0
n10
200
n11
50.0
n12
25
n13
50.0
n14
1.3
n15
10
Setting
n09
50.0
n10
200
n11
50.0
n12
2.5
n13
24
n14
1.3
n15
18