Constant No.
n76
• Prohibiting constant read selection (n77)
Select this function to prevent accidentally overwriting the constants
stored in EEPROM or in the digital operator. Reading is not possible
when this constant is set to 0.
The constant data stored in the digital operator are protected from
accidental overwriting.
When reading is performed while this constant is set to 0, PrE
will blink. Press the DSPL or ENTER and return to the constant No.display.
Constant No.
n77
76
Name
Constant copy
function
selection
Name
Constant read
selection
prohibit
Unit
Setting Range
rdy: READY
rEd: READ
CPy: COPY
vFy: VERIFY
vA: Inverter
capacity
display
Sno: Software
No. display
Unit
Setting Range
0: READ prohibited
1
1: READ allowed
Initial Setting
rdy
Initial Setting
0