Repair > Coffee Module repairs > Replace brewing unit (maintenance kit)
d
c
Fig. 80 
7. With the help of a small screwdriver, release the latch and unplug the coil connec-
tor (c, see detail).
8. Loosen 4 screws (crosshead) on the front assembly (d). These can be disposed of.
d
Fig. 81 
9. Remove and dispose of the front assembly (d).
Version 0.1 EN
Momento Service manual
99