3. At each coffee module: Touch the front cover with the test probe and insert the
test probe into the test hole which is located in the capsule ejection opening.
4. Drip tray: Remove the right drip grid and touch the contacts with the test probe
(see detail).
What to do if this test fails?
• Replace a defective assembly (e.g. coffee module).
• Perform troubleshooting and repair.
Version 0.1 EN
Final tests > Protective insulation resistance test
3
4
3
5
Momento Service manual
Fig. 94
Fig. 95
113