8. Unscrew 2 flat receptacles of the ground wire from thermoblock (C24) on the
power supply (C75).
9. Release the flat receptacle of the ground wire at the power supply (C75).
This kind of flat receptacle has a special connector latching.
Press down the lever with flat nose pliers while pulling on it.
10. Pull the wires out of the guides and wire saddles (C05).
11. Lift the thermoblock (C24) off of the coffee module.
Assembly tips
• Make sure that the cross beam (C69) screws are countered with a square nut.
• Only use the black coloured connector clips for the hose adapters (C80) connect-
ing directly to the thermoblock (C24).
• Always replace the O-ring (C81) seated between the thermoblock (C24) and hose
adapters (C80).
Version 0.1 EN
Repair > Coffee Module repairs > Replace thermoblock
C75
C24
Momento Service manual
Fig. 70 