Replace main PCB
C16,(C17)
Prerequisites
• Main PCB cover is removed → p. 74.
Procedure
1. Unplug all connectors and receptacles from the main PCB (C17).
2. Pull on the main PCB housing (C16) until you hear it click.
3. Lift the main PCB (C17) and housing (C16) out of its slots (circled in red).
Version 0.1 EN
Repair > Coffee Module repairs > Replace main PCB
Momento Service manual
The illustration
shown is with the
pump removed – for
better visibility.
Fig. 74
95