2. At each coffee module: Insert the test probe into the test hole which is located in
the capsule ejection opening.
3. Touch the bottom plate with the test probe.
What to do if this test fails?
• Remove the coffee modules. Check the ground wiring and ground terminals in the
main housing and coffee modules.
• Perform further, detailed measurements with the electric safety tester. Localize
and rectify any faults occurring.
• Check/replace the power cord.
Version 0.1 EN
Final tests > Protective earth (PE) resistance test
2
3
Momento Service manual
the capsule
containers must
be removed.
Fig. 90
Fig. 91
111