Chapter 17. General Routing Guidelines
17.1
Signal Naming Convention
The following conventions are used in describing the signals for Orin module:
Signal names use a mnemonic to represent the function of the signal. For example, I2S
interface #0 shift clock signal is represented as
signals are identified by an asterisk (*) after the signal name. For example,
indicates an active-low signal. Active-high signals do not have the (*) after the signal
names. For example,
identified as a pair with the same names that end with
respectively). For example,
The signal I/O type is represented as a code to indicate the operational characteristics of
the signal. The following table lists the I/O codes used in the signal description tables.
Table 17-1.
Signal Type Codes
Code
A
DIFF I/O
DIFF IN
DIFF OUT
I/O
I
O
OD
I/OD
P
PRELIMINARY INFORMATION
Jetson Orin NX Series and Jetson Orin Nano Series
indicates an active-high signal. Differential signals are
I2S0_FS
and
CSI_0_D0_P
CSI_0_D0_N
Definition
Analog
Bidirectional Differential Input/Output
Differential Input
Differential Output
Bidirectional Input/Output
Input
Output
Open Drain Output
Bidirectional Input / Open Drain Output
Power
. All active-low single-ended
I2S0_SCK
and
(for positive and negative,
_P
_N
indicate a differential signal pair.
DG-10931-001_v1.1 | 81
SYS_RESET*