HP 1660 Series Service Manual page 54

Logic analyzers
Hide thumbs Also See for 1660 Series:
Table of Contents

Advertisement

Set up the Format menu.
2 2
a a Press the Format key. Select State Acquisition Mode, then select Full Channel/4K
Memory/100MHz.
b b Select the field to the right of each pod, then select ECL in the pop-up menu. Use the
knob to access pods not shown on the screen.
Set up the Trigger menu.
3 3
a a Press the Trigger key. Select Clear Trigger, then select All in the pop-up menu.
b b Select Count Off. Press Select again, then select Time in the pop-up menu. Select
Done to exit the menu.
c c Select the field labeled 1 under the State Sequence Levels. Select the field labeled
"anystate," then select "no state." Select Done to exit the State Sequence Levels menu.
d d Select the field next to "a," under the label Lab1. Type the following for your logic
analyzer, then press the Select key.
HP 1660A–"00AA"
HP 1661A–"002A"
To test the single-clock, single-edge, state acquisition (logic analyzer)
HP 1662A–"00AA"
HP 1663A–"000A"
Testing Performance
3–25

Advertisement

Table of Contents
loading

This manual is also suitable for:

1660a series1660as series1660a1661a1662a1663a

Table of Contents