Medium Temperature Mode - Hussmann micro SC ARCH Series Installation & Operation Manual

Self-contained cold-wall bunker with lids
Table of Contents

Advertisement

P/N 3116321_A
MEDIUM TEMPERATURE MODE - FREEZER MODE CHANGE
1. Press and hold the PRG button + Down Arrow (AUX) button until "bn0"
appears in the display . During the process the controller will restart . Always
hold the button until "bn0" appears .
2. The display shows the value "bn0" .
3. Use the buttons "up" and "down" to switch between the possible settings:
a. bn1 – Freezer mode
b. bn2 – Medium Temperature mode
4. Press the "SET" button to select the desired mode . The controller will restart .
5. After restart, press the "SET" button to verify the Setpoint .
In medium temp mode the wire rack shelving
needs to be above the compressor bay to
prevent freezing of product.
NOTE:
In medium temperature mode, the products
should be used above the compressor bay line .
The temperature in the bottom could be too low .
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Island Self Contained R-290
3-5

Advertisement

Table of Contents
loading