Defrost Sequences; Merchandiser Electrical Data; Electrical Connections; Field Wiring - Hussmann Insight Installation & Operation Manual

Table of Contents

Advertisement

2-4

DEFROST SEQUENCES

Insight merchandisers require defrost cycles for
proper operation . Refer to the data sheets for
application data . The Time Clock initiates de-
frost . The evaporator fans continue to circulate
air across the evaporator coil, melting any frost
build-up .
If temperature termination is required, an
applicable defrost sensor must be installed on
the case .

MERCHANDISER ELECTRICAL DATA

Technical data sheets are also shipped with the
case . The data sheets provide merchandiser
electrical data, electrical schematics, parts lists
and performance data . Refer to the technical
data sheets and merchandiser serial plate for
electrical information .

ELECTRICAL CONNECTIONS

All wiring must be in compliance with NEC
and local codes . All electrical connections are
to be made in the electrical wireway or Handy
Box .
8 Ft Case
(2438 mm)
P/N 3032067_E
Offtime Defrost
12 Ft Case
(3658 mm)
U.S. & Canada 1-800-922-1919 • Mexico 01-800-890-2900 • www.hussmann.com

FIELD WIRING

Field wiring must be sized for component
amperes stamped on the serial plate . Actual
ampere draw may be less than specified .
Field wiring from the refrigeration control
panel to the merchandisers is required for de-
frost termination thermostats and for optional
refrigeration thermostats . When multiple
merchandisers are on the same defrost circuit,
the defrost termination thermostats are wired
in series .
a l w a y s c h e c k t h e s e r i a l p l a t e
f o r c o m p o n e n t a m p e r e s

IDENTIFICATION OF WIRING

Leads for all electrical circuits are identified by
colored plastic bands . These bands correspond
to the color code sticker (shown below) located
inside the merchandiser's wireway cover .