(3) Setting the number of times of thread trimming for sewing one piece of product
Set the number of times of thread trimming to be carried out until the production counter completes count-
ing.
1) Calling the count complete unit setting
screen
In the state where the count complete unit is
selected on the production parameter setting
screen, press edit key ❽
The count complete unit setting screen is
displayed A.
2) Setting the count complete unit
Enter the set value for the count complete unit B
by pressing data change key ❼
3) Determining the count complete unit set value
The set value is determined by pressing edit key ❽
parameter setting screen.
.
.