JUKI LBH-1790S Instruction Manual page 44

Hide thumbs Also See for LBH-1790S:
Table of Contents

Advertisement

No.
S040
Crosswise compensation of needle entry
of basting
This item sets the amount to move needle entry
position to the right or left when performing basting
more than two cycles.
Compensation of left side position of bast-
S041
ing
This item sets the amount to move the sewing
reference position of basting from the center of left
overedging to the right or left.
Compensation of right side position of
S042
basting
This item sets the amount to move the sewing
reference position of basting from the center of right
overedging to the right or left.
S044
Speed setting of basting
This item sets speed of basting.
S051
Left parallel section tension
This item sets needle thread tension at left parallel
section.
S052
Right parallel section tension
This item sets needle thread tension at right parallel
section.
S053
Left parallel section tension (1st cycle of
double stitching)
This item sets needle thread tension at left parallel
section of 1st cycle at the time of double stitching.
Right parallel section tension (1st cycle of
S054
double stitching)
This item sets needle thread tension at right parallel
section of 1st cycle at the time of double stitching.
Tension at 1st bar-tacking section
S055
This item sets needle thread tension at 1st bar-tack-
ing section.
Tension at 2nd bar-tacking section
S056
This item sets needle thread tension at 2nd
bar-tacking section.
Setting of needle thread tension at the
S057
start of sewing
This item sets needle thread tension of tie stitching
at the start of sewing.
S058
Setting of needle thread tension of basting
This item sets needle thread tension of basting.
S059
ACT timing adjustment at the start of 1st
bar-tacking
This item adjusts needle thread tension output start
timing at 1st bar-tacking section.
*1 : Displayed according to the shape
*2 : Displayed when it is set to with edit. Refer to
*3 : Displayed when the function is selected.
Item
"V-12. Method of setting sewing data with/without edit"
– 41 –
Setting range
Edit unit
0.0 to 1.0
0.1 mm
-2.0 to 2.0
0.1 mm
-2.0 to 2.0
0.1 mm
400 to 3600
100 sti/min
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
-5 to 5
1 stitch
Remarks
*3
*2, *3
*2, *3
*3
*2
*2, *3
*2, *3
*2
*3
*2
p.37.