Setup Screen - Miller Auto Continuum 500 Owner's Manual

Hide thumbs Also See for Auto Continuum 500:
Table of Contents

Advertisement

8-4. Setup Screen

1
4
7
10
13
1
Information Bar
Displays general information on welding pow-
er source, location, asset number, serial num-
ber, and display language.
2
Purge Time
Displays the length of time gas will flow when
the purge button is pressed. Edit button allows
time length to be changed.
3
Enabled Errors
Displays which system errors are enabled.
Click Edit to enable or disable system errors.
4
Jog Speed
Displays the minimum and maximum Jog
speeds in inches per minute (IPM). Edit button
allows minimum and maximum jog speed set-
ting to be changed for forward and reverse jog.
5
Ethernet Settings
Edit button allows user to change connectivity
settings.
6
Data Connections
Displays which data connections are enabled
or disabled.
7
Region
Displays current region. Edit button allows re-
gion to be changed.
8
Status
Displays the status of various system selec-
tions: English vs. Metric display values, Slope
Adjustment enable/disable, Synergic MIG en-
able/disable, CE/English weld library avail-
ability, Arc length command scaling
9
WiFi Settings
Edit button allows user to change WiFi
Settings.
10 Auto Thread
Displays the Load Rate in inches per minute
(IPM) and Torch Length (Inches) to determine
the length of time for Auto Threading. Edit but-
ton allows these parameters to be changed.
11 Wire Spool
2
6
8
Displays wire type, spool size, and amount of
wire remaining on the spool. Edit button allows
wire information to be changed or reset.
12 Weld Cable Setup
Displays length and diameter of positive and
negative weld leads, torch, and voltage feed-
back (VFB) method that are selected. Edit but-
ton allows these parameters to be changed.
13 Robot Options
Displays current robot connectivity options.
Edit button allows robot options to be
changed.
14 Dry Run
Allows an automated weld cell to cycle without
striking an arc by simulating the arc detected
signal back to the weld cell
15 Auto Calibration
Edit button will display last auto calibration,
give live feedback of auto calibration values.
OM-277115 Page 43
3
5
9
11
12
14
15

Hide quick links: