8-6. Data Management Screen

4
7
1
Productivity
Displays arc time and wire used in inches and
pounds. Click Reset Data to reset productivity
data.
2
Lifetime Information
Displays total arc time, arc starts, and wire
used over lifetime of unit.
3
Software Information
Displays the software revision.

8-7. Help Screen

1
1
Factory Reset button will take user to a Facto-
ry Reset screen. Read and follow all instruc-
tions on Factory Reset screen to perform a
Factory Reset.
4
Error Log
Displays the last error experienced by the
system.
View button displays a list of previous errors
and the time at which they occurred.
5
System Log
Displays the last entry into the system log.
2
2
View button displays a list of the entries made
to the system log and the time at which they
occurred.
6
Wire Usage
Displays the amount of wire used, the amount
remaining, and the date the spool was started.
Click Reset Data when starting a new spool.
7
Secondary Log
View button displays a list of secondary com-
pensation tests that were run, listing Pass/Fail
status, date/time test was run, torch resis-
tance, torch voltage, weld cable resistance,
weld cable voltage, and weld cable current.
3
3
5
6
.
The Help Screen contains
three drop down menus
which contain the features
on the Setup, Arc Manage-
ment and Data Management
screens.
1
Setup Information
Drop−Down Menu
2
Arc Management
Drop−Down Menu
3
Data Management
Drop−Down Menu
OM-277115 Page 45