Voltage Sensing Lead And Work Cable Connections For Multiple Welding Arcs - Miller Auto Continuum 500 Owner's Manual

Hide thumbs Also See for Auto Continuum 500:
Table of Contents

Advertisement

6-4. Voltage Sensing Lead And Work Cable Connections For Multiple Welding Arcs

A. Bad Setup
2
3
6
Current Flow Path
1
Welding Power Source
2
Electrode Cable
3
Feeder Cable
4
Work Cable
5
Voltage Sensing Lead
6
Robot
OM-277115 Page 28
.
Appearance of actual unit may differ from that shown.
1
5
4
7
7
Workpiece
This arrangement is a bad setup due to
sensing leads being directly in the current
flow path of the welding arc. Interaction
between welding circuits will affect voltage
drop in the workpiece. The voltage drop
1
5
2
3
6
across the workpiece will not be measured
correctly for the voltage feedback signal.
Voltage feedback to the welding power
sources will not be correct at either sense
lead and result in poor arc starts and arc
quality.
4