Section 4 − Specifications; Serial Number And Rating Label Location; Software Licensing Agreement; 350 Model Specifications - Miller Auto Continuum 500 Owner's Manual

Hide thumbs Also See for Auto Continuum 500:
Table of Contents

Advertisement

4-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the back. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Software Licensing Agreement

The End User License Agreement and any third-party notices and terms and conditions pertaining to third-party software can be found at
https://www.millerwelds.com/eula and are incorporated by reference herein.

4-3. 350 Model Specifications

.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-10 and 5-11 for information on
connecting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 1045F ( 405C).
Input
Rated Welding Output
Power
Three
350 A @ 34 V DC,
Phase
100% Duty Cycle
*While idling; Input amperage fluctuates while idling and is always less than one Ampere. Use one Ampere for power efficiency calculations.
4-4. 500 Model Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-10 and 5-11 for information on
connecting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 1045F ( 405C).
Input
Rated Welding Output
Power
Three
500 A @ 40 V DC,
Phase
100% Duty Cycle
*While idling; Input amperage fluctuates while idling and is always less than one Ampere. Use one Ampere for power efficiency calculations.
OM-277115 Page 12
SECTION 4 − SPECIFICATIONS
Amperage
Voltage
Range
Range
CC Mode
CV Mode
20-400 A
10-44 V
Amperage
Voltage
Range
Range
CC Mode
CV Mode
20-600 A
10-44 V
Amperes Input
Maximum
At Rated Load
Open-
Output 50/60 Hz,
Circuit
Three-Phase
Voltage
380 V
400 V
75
21.8
20.8
(0-1A*)
(0-1A*)
Amperes Input
Maximum
At Rated Load
Open-
Output 50/60 Hz,
Circuit
Three-Phase
Voltage
380 V
400 V
75
34.9
33.2
(0-1A*)
(0-1A*)
KVA
KW
380 V 400 V 380 V
400 V
14.4
14.4
13.8
13.8
(0.8*)
(0.8*)
(0.17*)
(0.17*)
KVA
KW
380 V 400 V 380 V
400 V
23.1
23.1
21.9
21.9
(0.8*)
(0.8*)
(0.17*)
(0.17*)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Auto continuum 350

Table of Contents