Top Vent Or Rear Vent Configuration - FireplaceXtrordinair 564 GSR2 25K CF Installation Manual

Table of Contents

Advertisement

10
Finalizing the Installation

Top Vent or Rear Vent Configuration

This appliance is shipped in the top vent configuration. To change to the rear vent configuration, follow
the directions below.
NOTE: the vent configuration affects several aspects of installation (framing, maximum vent rise,
maximum vent run). Make sure the vent configuration is correct prior to installation. You may wish to
configure the diffuser when changing the vent configuration.
NOTE: Use a magnetic-tipped
nutdriver on these screws - take
care to prevent the screws from
falling into the fireplace.
© Travis Industries
(for qualified installers only)
Remove the 4 screws securing the
outer flue assembly. Place the
screws and assembly aside.
Remove the 4 screws securing the
intake cover plate. Place the screws
and cover plate aside.
5/8/2019 - 1505
Remove the 4 screws securing the
inner flue assembly. Place the
screws and assembly aside.
Remove the 4 screws securing the
exhaust cover plate. Verify the gasket
on the cover plate is in place, then
attach it to the upper exhaust port with
the same screws.
564 GSR2 25K CF