FireplaceXtrordinair 564 GSR2 25K CF Installation Manual page 57

Table of Contents

Advertisement

Finalizing the Installation
Remove the manifold covers.
NOTE: Discard the orifice gaskets and reinstall the manifold covers after changing the orifices
3. Follow the directions below to replace the orifice.
a
Slide the air shutters to provide access to the orifices.
b
Remove and discard the gasket on each burner orifice.
Manifold
Front Burner Orifice
e
Screw each LP orifice until orifice
protrudes 15/16" (23.8mm)
indicating full insertion (use
wrench to support manifold when
re-attaching orifice).
© Travis Industries
9/16" Wrench
Rear Burner Orifice
(for qualified installers only)
Use a 9/16" wrench to support the
c
manifold while removing each
orifice with a 1/2" wrench.
1/2" Wrench
Apply thread sealant to the LP orifices
prior to installation. Use the chart below to
identify the correct orifices.
15/16"
23.8mm
5/8/2019 - 1505
d
Look here for the orifice identification
564 Orifice Numbers
NG
Front
#52
Rear
#51
564 GSR2 25K CF
57
LP
#60
#60