Finalizing the Installation
Converting the Fireplace to Rear Vent Configuration (continued)
Attach the heat shield
(included with the fireplace) to
the top of the fireplace. Use
the screws pre-attached to the
top of the fireplace.
Make sure the heat shield is
properly formed
(bend the mounting legs as shown).
© Travis Industries
Tuck the insulation (included in the rear vent conversion
kit) into the area above the exhaust manifold. NOTE: The
longer edge goes side to side. The insulation must be
placed so it covers the entire area over the exhaust
manifold.
Verify the gasket on the inner flue
assembly is in place, then attach it to
the exhaust port using the screws
removed earlier.
5/8/2019 - 1505
(for qualified installers only)
Verify the gasket on the intake cover plate
is in place, then attach it to the top of the
fireplace using the screws removed earlier.
Verify the gasket on the outer flue
assembly is in place, then attach it to
the fireplace using the screws
removed earlier.