Bsp-360 Battery Default Setting - Planet Switch User Manual

Industrial renewable power 5-port gigabit managed switch/router with 4-port 802.3at poe+
Table of Contents

Advertisement

Use Lithium battery for BSP-360. You could set the Battery type at Battery Management on the web of
BSP-360.
B.3 BSP-360 Battery Default Setting
Battery Information
Setting
FCV (Float Charge Voltage)
ACV (Absorption Charge Voltage)
LVD (Low Voltage Disconnection)
LVR (Low Voltage Reconnection)
Default Charge Board LVD
Default Charge Board LVR
Industrial Renewable Energy 4-Port 10/100/1000T
802.3at PoE+ Managed Ethernet Switch/Router
Type
Lithium Battery
(Default)
26.6V
28.7V
21.3V
24.0V
81
Lead-acid Battery
27.2 V
29.2 V
22.2 V
23.5 V
21.3 V
24.0 V