Battery Management - Planet Switch User Manual

Industrial renewable power 5-port gigabit managed switch/router with 4-port 802.3at poe+
Table of Contents

Advertisement

4.5 Battery Management

The page provides the user to configure the battery parameters so as to achieve the best application
condition as the screen in
Screen of Renewable Energy Switch. Before the configuration operation, please contact the suppliers of your
battery for the product‐specific parameters.
Object
Battery Type
Battery Capacity
Install Time of Battery
Battery Life
Fully-Charged Hold Time
Float Charge Voltage
Absorption Charge Voltage
Low Voltage Disconnection
Figure 4-5-1
appears.
Table 4-5-1
Figure 4-5-1
Battery Management Web Page Screen
Description
Lithium or Lead-acid battery.
Enter the Battery Capacity to the item.
Please ask the battery vendor about this information.
Enter the install time of battery to the item.
Enter the battery life to the item.
Please ask the battery vendor about this information.
When the battery is Fully-Charged, the controller will stop charging for a
while.
DC 27.2V ( 26.0~30.0V)
When the battery charge completes the charging process, its voltage will
drop to a float charge voltage and maintain at this voltage with a minimal
charging current for supplemental battery charging.
DC 29.2V (28.0~32.0V)
When the battery voltage achieves the value of absorption charge
voltage, the controller will maintain this voltage and charge for a period of
time which will not cause excessive charging of the battery.
DC 22.2V (21.0~23.0V)
When the battery voltage is less than the value for low‐voltage
Industrial Renewable Energy 4-Port 10/100/1000T
802.3at PoE+ Managed Ethernet Switch/Router
describes the Battery Management Objects
54