Table 4-6-5: Descriptions of the PoE Schedule Configuration Objects
Industrial Renewable Energy 4-Port 10/100/1000T
802.3at PoE+ Managed Ethernet Switch/Router
Description
Allows user to enable or disable per port PD Alive Check function. All ports
are disabled as default value.
This column allows user to set PoE device IP address here for system
making ping to the PoE device. Please note that the PD's IP address must
be set to the same network segment as the Renewable Energy Switch.
This column allows user to set how long system should issue a ping
request to PD for detecting whether PD is alive or dead. Interval time
range is from 10 seconds to 300 seconds.
This column allows user to set how many times system wants to retry ping
to PD. For example, if we set to count 2, the system will retry ping to the
PD for two times. If the PD doesn't response continuously, the PoE port
will be reset.
Allows user to set which action will be applied if the PD is without any
response. The Renewable Energy Switch offers 3 actions as follows:
PD Reboot: It means system will reset the PoE port that is connected to
the PD.
PD Reboot & Alarm: It means system will reset the PoE port and issue an
alarm message via Syslog,
Alarm: It means system will issue an alarm message via Syslog.
This column allows user to set the PoE device rebooting time. As there are
so many kinds of PoE devices on the market, they have different rebooting
times.
The PD Alive-check is not a defining standard, so the PoE device on the
market doesn't report reboots done information to the Ultra PoE Managed
Injector Hub. So user has to make sure how long the PD will be finished to
boot, and then set the time value to this column.
System is going to check the PD again according to the reboot time. If you
cannot make sure precise booting time, we suggest you set it longer.
Click to apply changes.
Refreshes the Web page and the current configuration if user doesn't save
it.