Planet Switch User Manual page 28

Industrial renewable power 5-port gigabit managed switch/router with 4-port 802.3at poe+
Table of Contents

Advertisement

(3) Connect the other points of DC power wires to the power devices. Tighten the wire-clamp screws for
preventing the wires from loosening.
(4) Install the terminal block on the BSP-360.
The voltage of DC out is based on the battery voltage and the maximum DC
a.
The wire gauge for the terminal block should be in the range from 16 to 20
b.
The external device should also be grounded properly.
c.
Please ensure the output voltage is correct for remote device. Otherwise, it will damage
your remote device.
Step 6. Connecting to PC or Your Remote Ethernet Network
After completing the above 6 steps, the BSP-360 is ready for service.
One Powered Device
Two Powered Devices
out from the BSP-360 is 24VDC, 2A.
AWG.
Industrial Renewable Energy 4-Port 10/100/1000T
802.3at PoE+ Managed Ethernet Switch/Router
28
BSP-360

Advertisement

Table of Contents