Ethernet (Lan) Ports; Establishing A Connection - Extron electronics FOX3 SR 301 User Manual

Fiber optic hdmi scaling receivers
Hide thumbs Also See for FOX3 SR 301:
Table of Contents

Advertisement

Ethernet (LAN) Ports

The rear panel Ethernet connector (see figure 2,
Ethernet LAN or WAN. Communications between the receiver and the controlling device is
via an SSH client, using port 22023. This connection makes SIS control of the unit possible
using a computer connected to the same LAN or WAN (see
Recommendations
Default IP address
To access the FOX3 receiver via the LAN port, the IP address, subnet mask, and the
gateway address for the devices are needed. If the addresses have not been changed, the
factory‑specified defaults are:
IP address
Gateway address 0.0.0.0
Subnet mask

Establishing a Connection

Establish a network connection to a FOX3 device as follows:
1.
Download the SSH software.
2.
Open the SSH software.
3.
Enter the IP address of the FOX3 device in the Host Name or IP address field.
NOTES:
4.
Enter 22023 in the Port field.
5.
The FOX3 device is password protected, so the appropriate name, admin or user, and
password must be entered.
If the login and password are correct, the device responds with a copyright
message including the copyright year, the name of the product, firmware version,
part number, and the current date and time.
If the login and password are incorrect, the Login prompt returns. Enter admin or
user and the password again.
NOTES:
FOX3 SR 301 and FOX3 SR 311 Scaling Receivers • SIS Configuration and Control
on page 10 to wire the LAN connector).
192.168.254.254
255.255.255.0
If the local system administrators have not changed the value, the default
Ethernet IP address is 192.168.254.254.
If connecting via the USB port, the IP address is 203.0.113.22.
The FOX3 device is shipped password‑protected. The factory configured
passwords for all accounts on this device have been set to the device serial
number.
In the event of a complete system reset, the password converts to the default,
which is extron. New passwords must be configured to secure the device.
On password‑protected connections, there are two levels of protection:
administrator and user. Administrators have full access to all capabilities and
editing functions. Users can view all settings with the exception of passwords.
on page 5) can be connected to an
I
TP Cable Termination and
22