3.
Press the ENTER button to accept the new value.
NOTE: To cancel a change, press the  button to return to the submenu list (left
column) without pressing ENTER. Then, press the  or  button to move to a
different submenu.
To exit the on-screen menu system:
From any menu screen, press the MENU button to close the on-screen menu and exit the
system.
The read-only DEVICE INFO screen
is displayed by default when the
OSD is first opened. It is listed first
in the submenus (left) panel. This
screen contains information about
The FOX3 scaling receiver, including
unit name, firmware version, internal
temperature in Celsius and Fahrenheit,
selected input device format and
signal information, and output signal
information for all outputs.

Quick Setup Submenu

The QUICK SETUP submenu is listed
second in the submenus (left) panel, and
provides quick access to frequently-
used settings. This submenu contains
the following items:
Output Rate — Press the  or
 buttons to select from a list of
output resolutions. Press the  or 
buttons to select from a list of refresh
rates (see the
page 26). The default setting is
1080p @ 60 Hz.
NOTES:
Resolution table
on
When a new resolution is
selected, the refresh rate
defaults to 60 Hz, except
for 576p, which defaults to
50 Hz.
If a new resolution is not
confirmed within 20 seconds,
the scaler reverts to the
previous resolution.
FOX3 SR 301 and FOX3 SR 311 Scaling Receivers • Operation
Figure 12.
Device Info Submenu
Figure 13.
Setup Submenu