Using verbose mode
SSH connections to a FOX3 device can be used to monitor for changes that occur on the
device, such as SIS commands from other SSH sockets or a serial port. For a SSH session
to receive change notices from the device, the SSH session must be in verbose mode 1 or
3 (see the SIS command

Simple Instruction Set Control

Host-to-Unit Instructions

SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command character sequence. When a command is valid, the
receiver executes the command and sends a response to the host device. All responses
from the receiver to the host end with a carriage return and a line feed (CR/LF =
signals the end of the response character string. A string is one or more characters.

Device-Initiated Power-Up Message

When the device completes its start‑up, it issues the following message to the host:
© Copyright 20yy, Extron FOX3 SR 301 (311) MM (SM), Vx.xx, 60‑nnnn‑nn
NOTE: This message only displays if the FOX3 device is connected to the serial port.

Error Responses

When the scaling receiver receives a valid SIS command, it executes the command
and sends a response to the host device. If the scaling receiver is unable to execute the
command because the command is invalid or it contains invalid parameters, the scaling
receiver returns an error response to the host. The error response codes are:

Timeout

Pauses of 10 seconds or longer between command ASCII characters result in a timeout.
The command operation is aborted with no other indication.
Verbose mode
20yy is the copyright year
Vx.xx is the firmware version number
60‑nnnn‑nn is the part number.
E10 — Invalid command
E11 — Invalid preset number
E13 — Invalid parameter
E14 — Invalid for this configuration
E17 — Invalid command for signal type
E18 — System or command timed out
FOX3 SR 301 and FOX3 SR 311 Scaling Receivers • SIS Configuration and Control
on page 28).
E21 — Invalid room number
E22 — Busy
E24 — Privilege violation
E25 — Device not present
E26 — Maximum number of connections
exceeded
E28 — Bad file name or file not found
]
), which
23