15 ELECTRICAL SYSTEM
15.4
118
Changing the main fuse
Warning
Fire hazard Incorrect fuses overload the electrical system.
–
Only use fuses with the required ampere value.
–
Do not bypass or repair fuses.
Info
The main fuse protects all power consumers of the vehicle.
E00361-10
Info
If the charging current, charging voltage and charg-
ing time are exceeded, electrolyte escapes through
the safety valves. This reduces the battery capacity.
If the battery is left in a discharged state for an
extended period, over-discharge and sulfating
occurs, destroying the battery.
The battery is maintenance-free. The acid level
does not have to be checked.
Never remove cover
Charge the battery to a maximum of 10% of the
capacity specified on battery housing
–
Switch off the battery charger after charging and discon-
nect from the battery.
Guideline
The charging current, charging voltage, and charging
time must not be exceeded.
Charge the battery regu-
larly when the motorcycle
is not in use
Finishing work
–
Install the battery.
(
–
Mount the seat. (
p. 78)
Preparatory work
–
Press and hold the kill switch
the engine stops.
–
Remove the seat. (
p. 77)
Main work
–
1
Pull starter relay
from the holder.
1
.
2
.
3 months
p. 114)
while the engine is idling until