The following parameters are those added to or modified in the MR-J2S-
MELSERVO-J2S-A Specifications and Installation Guide and Instruction Manual since they are the same as those of the
standard model.
Class
No.
Abbre
viation
0
STY
1
OP1
Note: After setting the values of the parameters marked
completes the setting.
Name and Function
Control mode, regenerative brake option selection
Select the control mode and regenerative brake option.
Control mode selection
0: Position
Regenerative brake option selection
0: Not used
1: Spare (Do not set)
2: MR-RB032
3: MR-RB12
4: MR-RB32
5: MR-RB30
6: MR-RB50
7: Spare (Do not set)
Note: Select the regenerative brake option compatible with the amplifier.
Incorrect setting will result in a parameter error.
Function selection 1
Select the input signal filter and CN1B-19 pin
function.
Input signal filter
0: None
1: 1.777msec
2: 3.555msec
3: 5.333msec
CN1B-19 pin function selection
0: Zero speed detection signal
1: Electromagnetic brake interlock signal
A-S091. For the other parameters, refer to the
8: MR-RB31
9: MR-RB51
A: Spare (Do not set)
, switch power off once. Switching power on again
-22-
Initial
Unit
Setting
Value
Range
0000
0000h
0A00h
0002
0000h
0013h
BCN-B32110-011