Batch Mode Quantity; Enter Quantities - Honeywell Xenon XP 195 Series User Manual

Area-imaging scanners and bases
Table of Contents

Advertisement

Flash Storage: The scanner writes any untransmitted data to flash memory prior to
powering down. The data will still be there when the scanner powers back up.
However, the scanner will power down, even with untransmitted data, if it reaches a
power down timeout or if the battery or charge pack power is very low.
RAM Storage: The scanner will not power down while it contains data that has not
been transmitted to the base or Access Point, even if it reaches a power down
timeout. However, if the scanner runs out of power, it will power down and the data
will be lost.
Default = Flash Storage.

Batch Mode Quantity

When in Batch Mode, you may wish to transmit the number of multiple barcodes
scanned, rather than a single barcode multiple times. For example, if you scan
three barcodes called XYZ with Batch Mode Quantity Off, when you transmit your
data it will appear as XYZ three times. Using Batch Mode Quantity On and the
Quantity Codes
Note: If you wish to format your output, for example, place a CR or tab between the barcode
data and the quantity, refer to
Default = Batch Mode Quantity Off.

Enter Quantities

Quantity Codes
up to 9999 (default = 1). Quantity digits are shifted from right to left, so if a fifth
digit is scanned, the first digit scanned is discarded and the second, third and
fourth digits are moved to the left to accommodate the new digit.
64
* Flash Storage
(page
* Batch Mode Quantity Off
(page
66), you could output your data as "XYZ, 00003" instead.
Data Format
66) allow you to enter a quantity for the last item scanned,
beginning on page 131.
Batch Mode Quantity On
Xenon XP User Guide
RAM Storage