Honeywell Xenon XP 195 Series User Manual page 130

Area-imaging scanners and bases
Table of Contents

Advertisement

Satisfactory Subset of Full Sequence Timeout Example
To specify a subset, list its members using the SEQSAT command and terminate
each subset with FF. The members of each subset are specified as single hex digits
corresponding to their index within the full sequence, 1 being the first. For
example, to specify two subsets, the first consisting of the first and second code in
the sequence and the second subset consisting of the second and third code, use
the command SEQSAT12FF23FF.
To define a subset with an odd number of codes, insert a 0 before the final code
index. For example, to define a 3-code subset consisting of the first, second, and
third codes, use the command SEQSAT1203FF.
In this example command SEQBLK62999943FF6A999954FF7299994DFF will
set the first code in the sequence to Code 39 "C", second code to Code 128 "T", and
third code to PDF417 "M".
The command SEQSAT01FF23FF will satisfy the sequence if either Position 1 is
scanned or Position 2 and 3 are scanned, it will send out the position 1 barcode or
Position 2 and 3 barcode right away.
Verify the below combination output sequence:
1. Scan Code 39. Output CODE39SMPL
2. Scan Code 128, and then scan Code 39 and wait for timeout. Output
3. Scan PDF417, and then scan Code 39 and wait for timeout. Output
4. Scan Code 128, and then scan PDF417. Output
5. Scan PDF417, and then scan Code 128. Output
Verify the combination with SEQTTS1:
112
SEQDFT;SEQ_EN1;SEQBLK62999943FF6A999954FF7299994DFF;SEQSEP993D3E;SEQSUF990D0A;
SEQSAT01FF23FF;SEQTIM5000FF6000FF7000FF8000FF.
CODE39SMPLTSTMSGCODE128
CODE39SMPLMSGPD417
TSTMSGCODE128MSGPDF417
TSTMSGCODE128MSGPDF417
SEQDFT;SEQ_EN1;SEQBLK62999943FF6A999954FF7299994DFF;SEQSEP993D3E;SEQSUF990D0A;
SEQSAT01FF23FF;SEQTIM5000FF6000FF7000FF8000FF;SEQTTS1.