5. Replace with the new cable. Insert the connector into the opening and press
Change a Scanner Battery
1. Grasp the wing connector or use a Phillips
2. Remove the end cap and remove the battery
3. Insert replacement battery.
4. Replace end cap and screw together.
Troubleshoot a Corded Scanner
The scanner automatically performs self-tests whenever you turn it on. If your
scanner is not functioning properly, review the following Troubleshooting Guide to
try to isolate the problem.
Is the power on? Is the aimer on?
If the aimer isn't illuminated, check that:
Is the scanner having trouble reading your symbols?
If the scanner isn't reading symbols well, check that the symbols:
Is the barcode displayed but not entered?
The barcode is displayed on the host device correctly, but you still have to press a
key to enter it (the Enter/Return key or the Tab key, for example).
294
firmly. The connector is keyed to go in only one way, and will click into place.
head screwdriver to remove the screw from
the end cap.
from the handle.
The cable is connected properly.
The host system power is on (if external power isn't used).
The trigger works.
Aren't smeared, rough, scratched, or exhibiting voids.
Aren't coated with frost or water droplets on the surface.
Are enabled in the scanner or in the decoder to which the scanner connects.
You need to program a suffix. Programming a suffix enables the scanner to
output the barcode data plus the key you need (such as "CR") to enter the data