Discard Partial Output Sequence
If you want to discard partial sequences when the output sequence operation is
terminated before completion, scan Discard Partial Sequence.
Output Sequence Timeouts
You can set a timeout for every code in the output sequence defined by the
SEQBLK command. The scanner applies the shortest timeout corresponding to
any of the codes that have been read during the current trigger session. When the
timeout expires, the scanner sends all codes that it has been read in the order they
appear in the sequence defined by SEQBLK.
To specify the timeout, use the SEQTIM command followed by a list of timeouts in
milliseconds. Each timeout is specified as a 4-decimal digit terminated by FF. The
timeout value 9999 is special and indicates that the timeout for that code is
"infinite".
The number of timeouts specified should correspond to the number of codes in the
sequence defined by SEQBLK. You can specify one additional timeout, which will
apply to codes not matching any member of the sequence. This can be useful if
Require Output Sequence is On/Not Required. If you do not specify an additional
timeout for codes not in the defined sequence, the last timeout specified by
SEQTIM will apply.
Output Sequence Timeout Example
For example, if SEQBLK defines a 4-code sequence, you can specify timeouts of 5,
6, 7, and 8 seconds for codes 1-4 respectively using the command
SEQTIM5000FF6000FF7000FF8000FF. Codes that are not part of the defined
sequence would have an implied timeout of 8 seconds in this case (the final
timeout in the list). To explicitly specify a timeout for such codes, you can include
one more timeout at the end of the list. For example, to include a timeout of 1
second for non-sequence codes, use the command
SEQTIM5000FF6000FF7000FF8000FF1000FF.
Satisfactory Subset of Full Sequence
You can define one or more subsets of barcodes from the complete sequence
specified by SEQBLK. When you scan all the codes from one of these subsets, the
scanner will transmit all the codes it has read in the sequence. The scanner sends
the codes in the order defined by SEQBLK.
Note: To use the satisfactory subset feature, you must supply a timeout for each code in the
sequence using SEQTIM.
Xenon XP User Guide
* Discard Partial Sequence
111