When Check Character is set to Validate and Transmit, the scanner only reads
Code 39 barcodes printed with a check character, and will transmit this character
at the end of the scanned data. Default = No Check Character.
Code 39 Message Length
Scan the barcodes below to change the message length. Refer to
Description
lengths = 0-48. Minimum Default = 0, Maximum Default = 48.
Minimum Message Length
Code 39 Append
This function allows the scanner to append the data from several Code 39
barcodes together before transmitting them to the host computer. When the
scanner encounters a Code 39 barcode with the append trigger character(s), it
buffers Code 39 barcodes until it reads a Code 39 barcode that does not have the
append trigger. The data is then transmitted in the order in which the barcodes
were read (FIFO). Default = Off.
156
* No Check Character
Validate and Transmit
(page 152) for additional information. Minimum and Maximum
On
Validate, but Don't Transmit
Message Length
Maximum Message Length
* Off