IBM x3250 M2 Problem Determination And Service Manual page 73

Hide thumbs Also See for x3250 M2:
Table of Contents

Advertisement

4. Carefully grasp the adapter by its top edge or upper corners and align it with
the expansion slot in the riser-card assembly; then, press the adapter firmly
into the expansion slot.
Important: Make sure that the U-shaped opening in the metal adapter bracket
engages the tab on the expansion-slot bracket.
5. Follow the cabling instructions, if any, that come with the adapter.
6. Carefully align the riser-card assembly with the guides on the rear of the
server and with the riser-card connectors on the system board; then, press
down on the assembly. Make sure that the riser-card assembly is fully seated
in the riser-card connector on the system board.
Power cable
7. If the riser-card assembly is an optional PCI-X riser-card assembly, reconnect
the riser-card power cable to the riser-card assembly.
8. If you are installing a ServeRAID-MR10i controller (2.5-inch drive models only),
complete the following steps:
a. Disconnect the existing SAS/SATA controller signal cable from the hard
disk drive backplane and from the controller; then, remove the cable from
the server.
b. Route the ServeRAID-MR10i signal cable as shown in the following
illustration and connect it to the hard disk drive backplane.
PCI-X slot
Chapter 4. Removing and replacing server components
55