IBM x3250 M2 Problem Determination And Service Manual page 189

Hide thumbs Also See for x3250 M2:
Table of Contents

Advertisement

Table 10. DSA diagnostic messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 3, "Parts listing, Types 4190, 4191 and 4194 server," on page 31 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
201-803-xxx
Memory
201-804-xxx
Memory
Test
State
Memory Test
Aborted
Memory Test
Aborted
Description
Action
Test canceled:
1. Turn off and restart the system.
could not enable
2. Run the test again.
the processor
cache.
3. Make sure that the BIOS code is at the
latest level. The installed firmware level
is shown in the DSA event log in the
Firmware/VPD section for this
component. For the latest level of
firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
4. Run the test again.
5. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.
Test canceled: the
1. Turn off and restart the system.
memory controller
2. Run the test again.
buffer request
3. Make sure that the BIOS code is at the
failed.
latest level. The installed firmware level
is shown in the DSA event log in the
Firmware/VPD section for this
component. For the latest level of
firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
4. Run the test again.
5. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.
171
Chapter 5. Diagnostics

Advertisement

Table of Contents
loading

Table of Contents