Table 10. DSA diagnostic messages
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 3, "Parts listing, Types 4190, 4191 and 4194 server," on page 31 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
089-801-xxx
CPU
Test
State
CPU Stress Test
Aborted
Description
Action
Internal program
1. Turn off and restart the system.
error.
2. Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
3. Run the test again.
4. Make sure that the system firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD section
for this component. For the latest level
of firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
5. Run the test again.
6. If the system has stopped responding,
turn off and restart the system.
7. Run the test again.
8. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.