v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Types 4190, 4191 and 4194 server," on page 31 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
1800
Unavailable PCI hardware interrupt.
1801
An adapter has requested memory
resources that are not available
1802
No more I/O space is available for a PCI
device
1803
No more memory available (above 1 MB)
1804
No more memory available (below 1 MB)
108
IBM System x3250 M2 Types 4190, 4191 and 4194: Problem Determination and Service Guide
Action
1. Run the Configuration/Setup Utility program and
adjust the adapter settings.
2. Remove each adapter one at a time, restarting
the server each time, until the problem is isolated.
1. Run the Configuration/Setup Utility program and
make sure that sufficient memory is installed in
the server.
2. Run the Configuration/Setup Utility program and
disable some other resources to make more
space available.
3. If possible, change the order of the adapters in
the PCI Express slots so that the device that
requires the most memory resources is positioned
early in the scan order (see the User's Guide for
information about the scan order).
4. Remove the adapter or disable BIOS on the
adapter to remove the request for memory
resources. See the documentation that comes
with the adapter for information about disabling
the adapter BIOS.
5. (Trained service technician only) Replace the
system board.
1. Run the Configuration/Setup Utility program and
make sure that interrupt resource settings are
correct.
2. If the error code indicates a particular PCI
Express slot or device, remove that device.
3. If the error continues, reseat each adapter.
4. (Trained service technician only) Replace the
system board.
1. If the error code indicates a particular PCI
Express slot or device, remove that device.
2. If the error continues, reseat each adapter.
3. (Trained service technician only) Replace the
system board.
1. If the error code indicates a particular PCI
Express slot or device, remove that device.
2. If the error continues, reseat each adapter.
3. (Trained service technician only) Replace the
system board.