Check Gas Connection; Check Flexible Conduits - Henny Penny FlexFusion FPG-221 Maintenance Instruction

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Checking the flexible conduit on the unit
Test criteria
If No
Change flexible conduit.

8.8 Check gas connection

Check gas connection line
Test criteria
• No damage, no creases.
• Firm fit.
• no unacceptable heating.
In case of no.
Inform the operator: The device must not be operated in a defective condition.
Do not carry out any further work.
Commission or plan repair work.
Check gas type
Test criteria
• Existing gas type matches the device setting.
In case of no.
Existing gas type does not match the gas type to which the device is set.
Inform operator: Do not carry out any further work. The unit must be switched to the correct gas type.
Checking the supply air and exhaust gas routing
Test criteria
• Supply air and exhaust gas ducting available.

8.9 Check flexible conduits

Check the flexible conduit in the unit
Test criteria
• Clamps are screwed on tightly.
If No
Tighten bolts or replace clamp.
Check tightness
Test criteria
• Hoses or flexible conduits are dry.
• No traces of moisture or corrosion visible.
If No
Change hose.
If replacement is not possible immediately, take the unit out of service.
Maintenance instructions
Performing maintenance
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No