Check Components Gas - Henny Penny FlexFusion FPG-221 Maintenance Instruction

Gas platinum combi incl. grease collection
Table of Contents

Advertisement

Performing maintenance
Check solenoid valve vapour release (service level / relay test)
Test criteria
If No
Troubleshooting according to service manual.
Inform operator.
Check siphon pump (service level / relay test)
Test criteria
• Siphon pump works perfectly.
If No
Troubleshooting according to service manual.
Inform operator.
Check pump circulation (service level / relay test)
Test criteria
• Pump circulation works properly.
If No
Troubleshooting according to service manual.
Inform operator.
Check motor cooking chamber for noise
Test criteria
• Motor cooking chamber runs virtually noiselessly.
If no
• Check fan wheel for imbalance.
• Recommendation of the manufacturer: Change motor and fan wheel.
Check electrical contacts - Carry out inspection of wiring harness (cable and contacts)
Test criteria
• Contacts are free of scorch marks.
If No
Change electronic components.

8.13 Check components gas

Action
• Switch on the ventilation system.
• Open the gas inlet.
• Switch on the device.
• In case of two devices next to each other - switch on both devices.
34
Maintenance instructions
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No